A: |
The
JH1000
can be configured to operate as four channel level converter, or ready
configured units can be obtained from us or your product distributor. To
change the unit's configuration please follow steps outlined below.
-
Obtain
a U22 integrated circuit (JH1000-PAL1) from your product distributor.
-
Disconnect
and remove cover from the unit.
-
Remove
U1, U6, U7, U8 and U9 from the unit.
-
Ensure
that the U18 and U19 are RS232 drivers (ADM232 or MAX232).
-
Ensure
that the MC3487 or equivalent IC is located in the U16 position.
-
Ensure
that the MC3486 or equivalent IC is located in the U17 position.
-
Ensure
that switches 3 and 4 are set to ON while all others switches remain in
the OFF
positions on the DIP switch S3.
-
Reassemble
cover.
Upon
modification the unit's ports will be assigned as shown below.
| Channel |
RS232 |
RS422 |
|
1 |
P1 |
P5 |
|
2 |
P2 |
P6 |
|
3 |
P3 |
P7 |
|
4 |
P4 |
P8 |
RJ45
pins arrangement for this unit are:
| Plug |
Pin |
Function |
Standard |
 |
1 |
Tx+ |
RS422 |
|
2 |
Tx-/Tx |
RS422/RS232 |
|
4 |
GND |
RS232 |
|
7 |
Rx-/Rx |
RS422/RS232 |
|
8 |
Rx+ |
RS422 |
|